Commissioning Proline Promass F 300 EtherNet/IP
120
Parameter Prerequisite Description Selection / User
interface / User
entry
Factory setting
Measuring value at minimum
frequency
In the Operating mode
parameter, the Frequency
option is selected, and one of
the following options is
selected in the Assign
frequency output parameter
(→  118):
Mass flow
Volume flow
Corrected volume flow
Target mass flow
*
Carrier mass flow
*
Density
Reference density
Concentration
*
Temperature
Carrier pipe temperature
*
Electronic temperature
Oscillation frequency 0
Frequency fluctuation 0
Oscillation amplitude 0
*
Oscillation damping 0
Oscillation damping
fluctuation 0
Signal asymmetry
Exciter current 0
Enter measured value for
minmum frequency.
Signed floating-point
number
Depends on country
and nominal
diameter
Measuring value at maximum
frequency
In the Operating mode
parameter, the Frequency
option is selected, and one of
the following options is
selected in the Assign
frequency output parameter
(→  118):
Mass flow
Volume flow
Corrected volume flow
Target mass flow
*
Carrier mass flow
*
Density
Reference density
Concentration
*
Temperature
Carrier pipe temperature
*
Electronic temperature
Oscillation frequency 0
Frequency fluctuation 0
Oscillation amplitude 0
*
Oscillation damping 0
Oscillation damping
fluctuation 0
Signal asymmetry
Exciter current 0
Enter measured value for
maximum frequency.
Signed floating-point
number
Depends on country
and nominal
diameter