Proline Promass F 300 EtherNet/IP Commissioning
121
Parameter Prerequisite Description Selection / User
interface / User
entry
Factory setting
Failure mode In the Operating mode
parameter, the Frequency
option is selected, and one of
the following options is
selected in the Assign
frequency output parameter
(→ 118):
• Mass flow
• Volume flow
• Corrected volume flow
• Target mass flow
*
• Carrier mass flow
*
• Density
• Reference density
• Concentration
*
• Temperature
• Carrier pipe temperature
*
• Electronic temperature
• Oscillation frequency 0
• Frequency fluctuation 0
• Oscillation amplitude 0
*
• Oscillation damping 0
• Oscillation damping
fluctuation 0
• Signal asymmetry
• Exciter current 0
Define output behavior in
alarm condition.
• Actual value
• Defined value
• 0 Hz
0 Hz
Failure frequency In the Operating mode
parameter, the Frequency
option is selected, and one of
the following options is
selected in the Assign
frequency output parameter
(→ 118):
• Mass flow
• Volume flow
• Corrected volume flow
• Target mass flow
*
• Carrier mass flow
*
• Density
• Reference density
• Concentration
*
• Temperature
• Carrier pipe temperature
*
• Electronic temperature
• Oscillation frequency 0
• Frequency fluctuation 0
• Oscillation amplitude 0
*
• Oscillation damping 0
• Oscillation damping
fluctuation 0
• Signal asymmetry
• Exciter current 0
Enter frequency output value
in alarm condition.
0.0 to 12 500.0 Hz 0.0 Hz
Invert output signal – Invert the output signal. • No
• Yes
No
* Visibility depends on order options or device settings