EasyManua.ls Logo

Epson AcuLaser C2800 - Level 2 FIP

Epson AcuLaser C2800
459 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AcuLaser C2800/C2800D/C3800/C3800D Revision C
TROUBLESHOOTING Engine-related Trouble FIP 121
Confidential
3.3.2 Level 2 FIP
FIP 2-1 REGI SENSOR
Possible parts that caused the error
Troubleshooting
FIP 2-2 SOLENOID FEED MSI
Possible parts that caused the error
Troubleshooting
HARNESS ASSY REGI SNR
HARNESS ASSY R SIDE
REGI SENSOR
PWBA MCU
Step Check Yes No
1
Check the connection of the REGI SENSOR
Check the connection state between REGI
SENSOR and PWBA MCU.
Are P/J23, P/J232, and P/J2322 connected
correctly?
Go to Step [2]. Reconnect P/J23,
P/J232, and
P/J2322 correctly.
2
Check the continuity of the HARNESS ASSY
REGI SNR
Is the continuity between P/J232 <=> P/J2322
normal?
Go to Step [3]. Replace the
HARNESS
ASSY REGI
SNR.
3
Check the continuity of the HARNESS ASSY
R SIDE
Is the continuity between P/J23 <=> P/J232
normal
?
Go to Step [4]. Replace the
HARNESS
ASSY R SIDE.
4
Check the power voltage supply to the REGI
SENSOR
Measure the voltage between PWBA MCU
ground <=> P/J23-8PIN.
Is the power voltage (approx. +3.3 V) output?
Go to Step [5]. Replace the
PWBA MCU.
(p.343)
5
Check the operation of the REGI SENSOR
Measure the voltage between PWBA MCU
ground <=> P/J23-10PIN.
Does the voltage change when the REGI
SENSOR is shielded from light?
Replace the
PWBA MCU.
(p.343)
Replace the REGI
SENSOR.
(p.253)
SOLENOID FEED MSI
HARNESS ASSY R SIDE
PWBA MCU
Step Check Yes No
1
Check the connection of the SOLENOID
FEED MSI
Check the connection state between
SOLENOID FEED MSI and PWBA MCU.
Are P/J23 and P/J256 connected correctly?
Go to Step [2]. Reconnect P/J23
and P/J256
correctly.
2
Check the continuity of the HARNESS ASSY
R SIDE
Is the continuity between P/J23 <=> P/J256
normal
?
Go to Step [3]. Replace the
HARNESS
ASSY R SIDE.
3
Check the power voltage supply to
SOLENOID FEED MSI
1. Close the interlock switch (HARNESS
ASSY INTERLOCK) before performing
the following work.
2. Measure the voltage between PWBA
MCU ground <=> P/J23-17PIN.
Is the power voltage (approx. +24 V) output?
Replace the
SOLENOID
FEED MSI.
(p.226)
Replace the
PWBA MCU.
(p.343)

Table of Contents