2.7.3  Process Control
In order to perform stabilized printing, it is necessary to adjust the parameters related to 
forming images on a timely basis. The control of whole print process including 
adjustment of the parameters is referred to as “process control”. Main controls are the 
following two controls. These controls are carried out after or during printing each time 
the number of printed pages exceeds 25 pages.
 Electric potential control
 Toner density control
The additional controls to cover the above two controls are as follows:
 High Area Coverage Mode
 Admix Mode
2.7.3.1  Electric Potential Control
To acquire stabilized print image density, drum charging voltage, developer DC 
charging voltage, and ROS Light Intensity should be adjusted depending on the 
developing performance which can be changed by various factors. The adjusted drum 
charging voltage, the developer DC voltage, and ROS Light Intensity are reflected in 
the print process control every time the adjustments are made.
Overview of the control is described below:
1. Detects temperature and humidity with the SENSOR HUM (temperature and 
humidity sensor).
2. Creates four patches (yellow, magenta, cyan, and black) onto the Transfer Belt for 
bias control.
3. Detects density of the patches on the Transfer Belt with an ADC sensor (density 
sensor).
4. Adjusts charged potential of the drum, developer DC voltage, and ROS light 
intensity for each color.