EasyManua.ls Logo

Epson AcuLaser C2800 - Page 126

Epson AcuLaser C2800
459 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AcuLaser C2800/C2800D/C3800/C3800D Revision C
TROUBLESHOOTING Engine-related Trouble FIP 126
Confidential
FIP 2-11 EXIT SENSOR (FUSER UNIT)
Possible parts that caused the error
Troubleshooting
FUSER UNIT
HARNESS ASSY FUSER
PWBA MCU
Step Check Yes No
1
Check the connection of the Exit Sensor in
the FUSER UNIT
Check the connection state between Exit Sensor
and PWBA MCU.
Are P/J17 and P/J171 connected correctly?
Go to Step [2]. Reconnect P/J17
and P/J171
correctly.
2
Check the continuity of the HARNESS ASSY
FUSER
Is the continuity between P/J23 <=> P/J232
normal
?
Go to Step [3]. Replace the
HARNESS
ASSY FUSER.
3
Check the power voltage supply to the Exit
Sensor in the FUSER UNIT
Measure the voltage between PWBA MCU
ground <=> P/J17-1PIN.
Is the power voltage (approx. +3.3 V) output?
Go to Step [4]. Replace the
PWBA MCU.
(p.343)
4
Check the operation of the Exit Sensor in the
FUSER UNIT
Measure the voltage between PWBA MCU
ground <=> P/J17-3PIN.
Does the voltage change when the Exit Sensor
is shielded from light?
Replace the
PWBA MCU.
(p.343)
Replace the
FUSER UNIT.
(p.298)

Table of Contents