AcuLaser C2800/C2800D/C3800/C3800D Revision C
TROUBLESHOOTING      Symptoms When Connectors are Disconnected 157
Confidential
PWBA MCU
Table 3-5.  PWBA MCU
Connector 
No.
Connected to Symptom
P10 BOARD ASSY, MAIN “Service Req C0998” occurs after turning the 
power on.
P11 BOARD ASSY, MAIN The printer starts up when the power is turned on, 
however, white or blank pages are printed.
P12 ROS ASSY “Service Req E100” occurs after turning the power 
on.
P14 LVPS, LED ASSY “Service Req C0998” occurs after turning the 
power on.
P15 LVPS “Printer Open” occurs after turning the power on 
though the cover assy front is closed.
P16 HVPS “Service Req E610” occurs after turning the power 
on.
P17 FUSER UNIT, LVPS “Install Fuser” occurs after turning the power on 
though the FUSER UNIT is installed properly.
P18 DISPENSER ASSY C/M/Y/K The printer starts up normally, however, print 
density becomes lower and lower in accordance with 
the print volume.
P19 SENSOR ASSY C/M/Y/K “Install CMYK TnrCart” occurs after turning the 
power on though the imaging cartridges are installed 
properly.
P21 MAIN MOTOR “Service Req E500” occurs after turning the power 
on.
P22 SUB MOTOR 
DEVE MOTOR
“Service Req E500” occurs after turning the power 
on.
P23 SWICTH ASSY SIZE 
CLUTCH ASSY PH FEED 
CLUTCH ASSY PH TURN 
CLUTCH ASSY PH REGI 
SOLENOID FEED MSI 
CST NO PAPER SENSOR 
REGI SENSOR
“Paper Out” occurs when trying to print though 
paper are loaded.
P24 PWBA OHP SENSOR 
PWBA OHP LED
“Service Req E610” occurs after turning the power 
on.
P25 DRIVE ASSY PH “Service Req E500” occurs after turning the power 
on.
P26 SENSOR HUM “Service Req E610” occurs after turning the power 
on.
P27 PWBA FEED-H 
MSI NO PAPER SENSOR 
PWBA EEPROM 
EXIT CLUTCH 
TRANSFER UNIT 
PWBA DUP
“Service Req E610” occurs after turning the power 
on.
P31 CRUM SENSOR C/M/Y/K “TonerCart Error” occurs after turning the power 
on.
Table 3-5.  PWBA MCU
Connector 
No.
Connected to Symptom
P10
P11
P14P19
P15
P18
P22
P21
P25
P23
P17 P16 P12
P27 P26
P24
P31