AcuLaser C2800/C2800D/C3800/C3800D Revision C
DISASSEMBLY/REASSEMBLY Disassembly/Reassembly 293
Confidential
5. Remove the six screws (silver, 6 mm) that secure the LVPS to the SHIELD LVPS.
6. Remove the LVPS from the SHIELD LVPS.
Kmy03066EB
5)
5)
5)
5)
5) 5)
6)
LVPS
ROS ASSY
1. Disconnect connector of the ROS ASSY (P/J12) on the PWBA MCU.
2. Remove the CORE TC-18-10-10 from the harness of the ROS ASSY, and pull out the connector
through the hole in the SHIELD MCU.
NEXT>>
B
Kmy03032E
1)
2)-1
2)-2