DISASSEMBLY/REASSEMBLY Disassembly/Reassembly 336
Confidential
HARNESS ASSY INLET
NEXT>>
C
Kmy03095EA
1)
2)
3)
4)
4)
4)
4)
4)
5)
5)
5)
HARNESS
ASSY INLET
1. Disconnect the connector (P/J48) of the HARNESS ASSY INLET on the LVPS.
2. Disconnect the connector (P/J481) connected to the SWITCH POWER.
3. Remove the screw (silver, external tooth washer, 6 mm) that secures the ground terminal of the
HARNESS ASSY INLET to the main unit.
4. Disengage the five cable ties that secure the HARNESS ASSY INLET to the main unit.
Attach the cable ties to the holes with triangular marks.
5. Release the HARNESS ASSY INLET from the three EDGE SADDLEs and the two clamps.
Pass the ground wire (green) of the HARNESS ASSY INLET through the clamp attached
to the SWITCDH ASSY SIZE.
Be careful not to damage the frame or other parts when cutting the cable tie.
6. Cut the cable tie attached to the tab in the AC inlet section with a nipper or a similar tool.
7. Release the tab in the AC inlet section and remove the HARNESS ASSY INLET from the main unit.