AcuLaser C2800/C2800D/C3800/C3800D Revision C
DISASSEMBLY/REASSEMBLY Disassembly/Reassembly 363
Confidential
COVER LEFT
1. Remove the two screws (silver, brimmed, 8 mm) that secure the COVER LEFT to the FRAME
ASSY OPT.
2. Release the two tabs that secure the COVER LEFT to the FRAME ASSY OPT.
3. Pull the protrusion of the COVER LEFT out of the concave surface of the FRAME ASSY OPT, and
remove the COVER LEFT.
C
Kmy03232E
1)
1)
2)
3)
COVER LEFT
GUIDE ASSY 550 L
1. Remove the screw (silver, self-tapping, 8 mm) that secures the GUIDE ASSY 550 L to the FRAME
ASSY OPT.
2. Release the tab that secures the GUIDE ASSY 550 L to the FRAME ASSY OPT, temporarily move
the GUIDE ASSY 550 L toward front to release the nine tabs, and remove the GUIDE ASSY 550 L
by laying it down inward.
C
Kmy03240EB
1)
2)-1
2)-2
2)-4
2)-3
GUIDE ASSY 550 L