Epson DFX 9000 Revision B
Disassembly and Assembly CES SCALE 160
4. Remove the C.B.S. 3 × 6 screw that secures the left end of the CES
SCALE to the inside of the SIDE FRAME, LEFT, and slowly pull
the CES SCALE out from the CES sensor on the bottom of the
CARRIER UNIT.
Figure 4-38. CES SCALE Removal (2)
Figure 4-39. CES SCALE Removal (3)
Attach the left end of the CES SCALE to the inside of
the SIDE FRAME, LEFT with the mark facing the
interior of the printer, as shown in Figure 4-38.
Make sure that the CES SCALE passes through the slit
in the CES sensor.
Match the positioning dowel on the SIDE FRAME,
LEFT with the positioning hole of the CES SCALE.
C A U T I O N
When placing the CES SCALE inside the CES sensor, take
care not to bend or damage the CES SCALE.
Reassembly
CES SCALE
Dowel
4)-1
mark
4)-2
CES sensor
CARRIER UNIT