Epson DFX-9000 Revision B
Product Description Basic specifications 32
1.2.8.6 Optional interfaces
Type-B optional interface cards are available, including Type-B I/F
Level 1 & Level 2 cards, and a simplified serial I/F Card. The main and
optional commands supported by each are shown in the tables below:
Table 1-25. Reply for Type-B I/F Level 2 main command
Main
command
number
Command name Transmission timing
01h Start Software Reset Init signal on the std. Parallel
Type B I/F Option command:
01h
Panel Reset
Cold start
02h Send Option Type Determines the level of Type-B I/
F after powered on
04h Send Name Data Type B I/F Option command: 05h
07h Inquire Software
Emulation Type
Changing control language
0Eh Inquire ASCII
Message
Writing to DBIN-register
14h Inquire Emergency
Reply
Reply for background job
command response
15h Send Emergency
Message
Receive background job command
16h Inquire Network
Settings
Request to send Network Settings
OPCMD
18h Start Shutdown Request to execute Shutdown of
the Type-B I/F Card