Epson DFX 9000 Revision B
Adjustment Hardware adjustment 230
Adjustment Procedure
1. Assemble the APG Gauge Jig (attach the Dial-Gauge to the Dummy-
Head), and adjust the 0 (zero) position of the Dial gauge. Refer to
APG Gauge Jig (p. 215) for details.
2. Install the APG Gauge Jig on the carriage unit. See Figure 5-11.
Figure 5-11. Mounting the APG Gauge Jig
C H E C K
P O I N T
Before performing this adjustment, remove these parts:
Ribbon Cartridge
FRONT COVER ASSY
REAR UNIT
OP UNIT
UPPER UNIT
PRINT HEAD
W A R N I N G
Turn the printer off and disconnect the AC cable before
you perform the following work.
Fastening bolts
APG Gauge Jig