Epson DFX 9000 Revision B
Adjustment Software adjustment 244
10. If the gap is outside the specified range, move the Carriage to the
first position (11th column) and adjust the gap by pressing the
[Micro Feed] buttons on Operation Panel.
11. When the gap values at each position are within specifications, press
the [Pause] button to register the adjustment value.
12. Turn OFF the printer to save the values to EEPROM.
13. Move the Carriage to the Ribbon cartridge replacement position, and
remove Dial-Gauge from the Dummy-Head, and install the ribbon
cartridge.
14. Close the top cover and turn the printer ON.
15. Set a single sheet of 64 g/m
2
(17 lb) paper on the front tractor and
load it by pressing the [Load] button.
16. In the Adjustment Program, click Enter adjustment mode.
17. Open the top cover and move the carriage to the Ribbon cartridge
replacement position by hand.
18. Remove the Ribbon Cartridge and attach the Dial-Gauge to the
Dummy-Head on the Carriage.
19. Move the carriage to three measurement positions, and verify that
the value on the Dial-Gauge is still within the Verification value
specifications: 0.31 mm ± 0.03 mm at all three positions.
20. If any gap is outside the specifications, adjust the gap by pressing the
[Micro Feed] buttons on panel.
21. When the gap values each position are within specification, press the
[Pause] button to register the adjustment value.
22. Turn OFF the printer.
23. Move the Carriage to the Ribbon cartridge replacement position and
remove the Dial-Gauge and install the Ribbon Cartridge.
24. Close the top cover and turn ON the printer again.
25. Set 10 sheets of 50 g/m
2
(13 lb) paper on the front tractor and load it
by pressing the [Load] button.
26. Repeat step 16 to step 19 again. If any gap measurement is outside
the specification, repeat step 20 to step 21.
27. Turn OFF the printer.
28. Move the Carriage to the Ribbon cartridge replacement position and
remove the Ribbon cartridge and all the Jigs.
C H E C K
P O I N T
The adjustable range is ±25 steps, where 1 step = 0.005 mm
C A U T I O N
After registering the adjustment value by pressing the
[Pause] button, be sure to turn OFF the printer. The
registered value is only stored in EEPROM during the
power OFF process.