5. General Maintenance
Safety and Installation (RC90 / EPSON RC+ 7.0) Rev.5
98
5.1.2 Controller
Part
Fan filter
Fan
Battery
Content
Cleaning
Replacement
Replacement
Replacement
Code
-
R13B60511
R13B060510
R13B060003
Quantity
-
1
1
1
Maintenance
interval
More than once
a month is
recommended
When the filter
gets deteriorated
When the error
515 occurs, or
when the
abnormal noise
occurs
Every 5 years,
or when the
error 511 occurs
Possible
malfunction if
maintenance
is not performed
The temperature
inside the
Controller may
get too high and
the robot system
may not operate
properly.
The error may
occur due to
reduction of the
fun rotation.
The robot system
may not operate
properly due to
dust or the like.
The error 9015
occurs and the
robot system
may stop.
The error 9011
occurs and the
robot system
may stop.
Duration
(reference)
5 minutes 5 minutes 20 minutes 15 minutes
Reference:
Maintenance
7.1
Fan Filter
7.1
Fan Filter
7.2
Fan
7.3
Battery
Expected
product life
- -
30,000 hours
-

Table of Contents