OPERATION
6-32
6.12.1 OUTPUT WIRE-GUIDE REMOVAL/INSTALLATION
1. Loosen the Output Wire-Guide thumb screw (see Figure 6-30).
2. Remove the Output Wire-Guide Tube out-through and out-of the CSA adapter
Assembly.
3. Replace with the new, correct-size tube in the reverse order. Do NOT tighten its set-
screw now (will be done below in ADJUSTING WIRE GUIDES).
6.12.2 CENTER WIRE-GUIDE REMOVAL/INSTALLATION
1. Loosen and remove the original Center Wire-Guide Tube (see Figure 6-30 for
location). This Center Wire-Guide Tube removes/installs only from the left side.
2. Install the new Center Wire-Guide Tube. Slide this tube (narrow part first and from
the left side) into its center post until it stops and hand-tighten its set screw.
6.12.3 ADJUSTING WIRE GUIDES
1. Verify Center Wire-Guide Tube has clearance from each Feed-Roller. The Center
Wire-Guide Tube set screw should be finger-tight (see Figure 6-33, Figure 6-30). The
Center Wire-Guide Tube requires no adjustment, but it must be inserted completely
to assure clearance from the rollers.
2. Adjust the Output Wire-Guide Tube for one mm (1 mm) of clearance from the right
Feed-Roller Verify Center Wire-Guide Tube has clearance from each Feed-Roller.
(see Figure 6-33) and tighten its thumb screw finger-tight.