EasyManua.ls Logo

ESAB EMP 285ic 3ph - Adjusting Wire Guides; Output Wire-Guide Removal;Installation; Center Wire-Guide Removal;Installation

ESAB EMP 285ic 3ph
107 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPERATION
6-32
6.12.1 OUTPUT WIRE-GUIDE REMOVAL/INSTALLATION
1. Loosen the Output Wire-Guide thumb screw (see Figure 6-30).
2. Remove the Output Wire-Guide Tube out-through and out-of the CSA adapter
Assembly.
3. Replace with the new, correct-size tube in the reverse order. Do NOT tighten its set-
screw now (will be done below in ADJUSTING WIRE GUIDES).
6.12.2 CENTER WIRE-GUIDE REMOVAL/INSTALLATION
1. Loosen and remove the original Center Wire-Guide Tube (see Figure 6-30 for
location). This Center Wire-Guide Tube removes/installs only from the left side.
2. Install the new Center Wire-Guide Tube. Slide this tube (narrow part first and from
the left side) into its center post until it stops and hand-tighten its set screw.
6.12.3 ADJUSTING WIRE GUIDES
1. Verify Center Wire-Guide Tube has clearance from each Feed-Roller. The Center
Wire-Guide Tube set screw should be finger-tight (see Figure 6-33, Figure 6-30). The
Center Wire-Guide Tube requires no adjustment, but it must be inserted completely
to assure clearance from the rollers.
2. Adjust the Output Wire-Guide Tube for one mm (1 mm) of clearance from the right
Feed-Roller Verify Center Wire-Guide Tube has clearance from each Feed-Roller.
(see Figure 6-33) and tighten its thumb screw finger-tight.

Table of Contents