IEEE 488.2 and Specific Command Reference
FTB-1v2 and FTB-1v2 Pro 411
Specific Commands
:INSTrument:CATalog?
Description The INSTrument:CATalog? query returns a
comma-separated list of <STRING RESPONSE
DATA>, which contains the names of all logical
instruments and groups. If no logical instruments
are defined, a single null <STRING RESPONSE
DATA> is returned.
This is not affected by a *RST command.
Syntax :INSTrument:CATalog?
Parameter(s) None
Response Syntax <Catalog>
Response(s) Catalog:
The response data syntax for <Catalog> is
defined as a <STRING RESPONSE DATA>
element.
The list of <STRING PROGRAM DATA> contains
the names of all logical instruments and groups.
Example(s) INST:CAT? returns “FTB-5240BP Optical
Spectrum Analyzer
(1250nm-1650nm)”,”FTB-5240S Optical
Spectrum Analyzer (1250nm-1650nm)”
See Also INSTrument:CATalog:FULL?