Summit X450e Series Switches
Summit Family Switches Hardware Installation Guide
449
Summit X450e-24t Power
Operational voltage range 90 to 264 V
Nominal input ratings 100 to 240 V , 50/60 Hz, 1.0 A
Nominal input current 0.52 A @ 100 V (low-line)
0.31 A @ 240 V (high-line)
Line frequency range 47 to 63 Hz
Inrush current 30 A @ 115 V, 60 A @ 230 V
Power supply cord type AC
Power supply input socket IEC 320 C14
Power cord input plug IEC 320 C13
Power cord wall plug Refer to “Power Cord Requirements for AC-Powered Switches and
AC Power Supplies” on page 500.
Power supply cord gauge 18 AWG (0.75 mm
2
) up to 6 feet or 2 meters
or
16 AWG (1.0 mm
2
) over 6 feet
Heat dissipation, Watts, BTU 52 W (178 BTU/hr)
Power consumption, Watts, BTU 52 W (178 BTU/hr)
Summit X450e-48t Power
Operational voltage range 90 to 264 V
Nominal input ratings 100 to 240 V , 50/60 Hz, 6 A
Nominal input current 0.94 A @ 100 V (low-line)
0.43 A @ 240 V (high-line)
Line frequency range 47 to 63 Hz
Inrush current 30 A @ 115 V, 60 A @ 230 V
Power supply cord type AC
Power supply input socket IEC 320 C14
Power cord input plug IEC 320 C13
Power cord wall plug Refer to “Power Cord Requirements for AC-Powered Switches and
AC Power Supplies” on page 500.
Power supply cord gauge 18 AWG (0.75 mm
2
) up to 6 feet or 2 meters
or
16 AWG (1.0 mm
2
) over 6 feet
Heat dissipation 94 W (321 BTU/hr)
Power consumption 94 W (321 BTU/hr)
Safety Standards
North American Safety of ITE UL 60950-1:2003 1st Ed., Listed Device (US)
CSA 22.2#60950-1-03 1st Ed.(Canada)
Complies with FCC 21CFR 1040.10 (US Laser Safety)
CDRH Letter of Approval (US FDA Approval)
IEEE 802.3af 6-2003 Environment A for PoE Applications
European Safety of ITE EN 60950-1:2001+A11
EN 60825-1+A2:2001 (Lasers Safety)
TUV-R GS Mark by German Notified Body
73/23/EEC Low Voltage Directive
International Safety of ITE CB Report & Certificate per IEC 60950-1:2001 Country Deviations
AS/NZX 60950-1 (Australia /New Zealand)
Table 87: Summit X450e Series Switch Technical Specifications (Continued)