IN1608 xi Scaling Presentation Switcher • Internal Web Pages 117
NOTES:
• Amplified output is for amplifier and IPCP models only.
• By default, all possible group members are selected for groups 1-7.
• The default selected group members for group 8 are amplified output (amplifier and
IPCP models only) and variable analog output.
To configure the groups:
1. Click the Mix Controls tab (see figure 68,
1
, on page 108).
2. In the Group Controls panel, click the Configure Groups button (
¢
). The Configure
Groups dialog box opens.
Figure 75. Configure Groups Dialog Box
3. For the desired group master, click the corresponding drop-down menu
(see figure 75,
1
) to display a list of available group members.
When changes are made to the associated control in the software, only the selected
group members are affected (see the table on the previous page).
To assign a volume control to the front panel volume knob:
1. Click the Mix Controls tab (see figure 68,
1
, on page 108).
2. In the Group Controls panel, click the Configure Groups button (
¢
). The Configure
Groups dialog box opens.
3. From the Front Panel Volume Knob list (see figure 75,
2
), select the desired volume
control the front panel volume knob adjusts. The available options are:
• Program Volume (Group #1) — Adjusts the program audio (default).
• Mic Volume (Group #3) — Adjusts microphone volume.
• Output Volume (Group #8) — Adjusts the output volume.
Group members
Group members are individual controls that comprise the group master. They can be
controlled individually, allowing for relative levels between members to be adjusted.
NOTE: Individual members of a mute group master that are muted outside of the group
master remain muted regardless of the current group master state.