IN1608 xi Scaling Presentation Switcher • SIS Configuration and Control 50
X(
= Enable or disable 0 = off or disabled
1 = on or enabled
X1)
= Input standard 0 = no signal detected on the current
input
1 = NTSC 3.85
2 = PAL
3 = NTSC 4.43
4 = SECAM
– = N/A (occurs when the input is active RGB,
YUV, or HDMI signal)
X1!
= Internal temperature In degrees Celsius
X1@
= Film detect mode 0 = disabled
1 = auto (default)
X1#
= Horizontal and vertical
frequencies
nnn.n
X1$
= Text label Up to 63 characters, with the following
restrictions:
• Only alphanumeric characters, the
underscore (_), and the hyphen (-) can be
used.
• 1 to 52 characters are permitted.
• The first character must be a letter.
• The last character cannot be a hyphen.
X1%
= Picture adjustment 0-127 (64 = default)
X1^
= Horizontal position
±2048
X1&
= Vertical position
±1200
X1*
= Horizontal size
10-04096
X1(
= Vertical size
10-02400
X2)
= Test patterns 0 = off (default)
1 = crop
2 = alternating pixels
3 = color bars
4 = grayscale
5 = blue mode
6 = audio test pattern (pink noise)
X2!
= User presets
01-16
X2@
= Input presets
1-128
X2#
= On-screen display bug
time-out Output sync time-
out
0 = OSD is never displayed, output sync is
instantly disabled with no active input
1-500 = 1 second increments
3 = OSD bug time-out default
501 = OSD bug never times out,
output sync never times out
X2$
= Front panel lockout
(executive mode) status
0 = off or disabled (default)
1 = mode 1 (complete front panel lockout)
2 = mode 2 (only allow input switching and
volume control)