IN1608 xi Scaling Presentation Switcher • SIS Configuration and Control 71
Command ASCII Command
(Host to Scaler)
Response
(Scaler to Host)
Additional Description
Device Commands
On-screen Input “Bug” Timeout
NOTE: The OSD bug is a floating message displayed after selecting a new input.
Set OSD bug time-out
EX2#
MDUR
}
Mdur
X2#]
Set the duration the OSD bug
displays to
X2#
seconds
(003 = default).
View time-out
E
MDUR
} X2#]
In verbose modes 2 and 3:
Mdur
X2#]
View OSD duration
X2#
.
NOTE: Setting the time-out to 501 permanently displays the OSD bug (never times out). Setting the time-out to 0 disables
the OSD bug.
Reset
Erase user-supplied web
pages and files
24, 28
E
filenameEF
}
Del
filename
]
Delete imported web pages and
files.
Erase current directory and
files
24 28
E
/EF
}
Ddl
]
Delete the current directory and files.
Erase current directory and
subdirectories
24, 28
E
//EF
}
Ddl
]
Delete the current directory and
subdirectories.
Erase flash memory
24
E
ZFFF
}
Zpf
]
Clear the flash memory.
Reset all device settings to
factory default
24
E
ZXXX
}
Zpx
]
Reset all device settings to factory
default.
Absolute system reset
24
(includes setting DHCP: off;
IP 192.168.254.254)
E
ZQQQ
}
Zpq
]
Reset all device settings, including
DHCP and IP settings.
Absolute system reset
24
(retain IP)
E
ZY
}
Zpy
]
Reset all device settings, excluding
IP settings.
Verbose mode
Set verbose mode
EX5#
CV
}
Vrb
X5#]
Enable or disable verbose mode and
tagged responses, where additional
information is provided in response
to a query.
View verbose mode
E
CV
} X5#]
In verbose modes 2 and 3:
Vrb
X5#]
View the verbose mode.
NOTES:
X2#
= On-screen display bug time-out
1-500 (in 1-second increments).
0 = OSD bug is never displayed.
3 = default.
501 = OSD bug never times out.
X5#
= Verbose mode
0 = clear or none (default for Telnet connections)
1 = verbose mode (default for RS-232 and USB connections)
2 = tagged responses for queries
3 = verbose mode and tagged queries
(See the Verbose Mode symbol definition on page 52 for more
information.)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extron electronics IN1608 xi IPCP SA with LinkLicense and is the answer not in the manual?

Extron electronics IN1608 xi IPCP SA with LinkLicense Specifications

General IconGeneral
BrandExtron electronics
ModelIN1608 xi IPCP SA with LinkLicense
CategoryMedia Converter
LanguageEnglish

Related product manuals