IN1608 xi Scaling Presentation Switcher • SIS Configuration and Control 76
Command ASCII Command
(Host to Scaler)
Response
(Scaler to Host)
Additional Description
Ethernet to RS-232 Insertion (continued)
Ethernet Data Port
Set current connection port
timeout
24
E
0*
X6^
TC
}
Pti0*
X6^]
Set the number of seconds before
the current port timeout to
X6^
.
View current connection
port timeout
E
0TC
} X6^]
In verbose modes 2 and 3:
Pti0*
X6^]
View the current port timeout setting
(
X6^
).
NOTE: The Set and View current connection port timeout commands are available only with an Ethernet connection.
Set global IP port timeout
24
E
1*
X6^
TC
}
Pti0*
X6^]
Set the number of seconds before
all ports time out to
X6^
.
View global IP port timeout
E
1TC
} X6^]
In verbose modes 2 and 3:
Pti1*
X6^]
View the global port timeout setting
(
X6^
).
Set UART start point
EX6&
MD
}
Pmd
X6&]
Set current UART starting port to
X6&
.
View UART start point
EMD} X6&]
In verbose modes 2 and 3:
PtiO*
X6&]
View the UART starting port number
(
X6&
).
NOTES:
X6^
= Port timeout
Set in increments of 10 seconds:
1 (10 seconds) to 65000 (650,000 seconds)
Default = 30 (300 seconds)
X6&
= Start point for UART ports
Controller RS-232 = port 1024
Port number range = 1024-65533

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Extron electronics IN1608 xi IPCP SA with LinkLicense and is the answer not in the manual?

Extron electronics IN1608 xi IPCP SA with LinkLicense Specifications

General IconGeneral
BrandExtron electronics
ModelIN1608 xi IPCP SA with LinkLicense
CategoryMedia Converter
LanguageEnglish

Related product manuals