A1400 AIR 39 532129 04 - Rev.B
50
49
1
2
3
2
1
1
3
3
8
7
7
6
1
6
2
7
6
4
Nm
3
8
9
Nm
4
9
Translation of the original instructions
ENGLISH
- 120 - 118 for DOUBLE leaf automations
6. Fasten the lower plate onto the leaf gripper using the 2 screws
50-
7. Lift the leaf until the upper and lower plates of the carriage come
into contact 50-
. The slots must be aligned.
For manual lifting, arrange for an adequate number of people for the
weight of the leaf: 1 person for every 20 kg to be lifted.
!
Use suitable glazing suction cups.
8. Fasten the 2 plates of the carriage together 50-
.
9. Adjust the counter wheel 50-
(see 37).
10. Insert the end cover 50-
.
!
Check leaf verticality.
When the leaf is open or closed, the shoe must be fully inside the lower
leaf profile.
The distance between glass and lower shoe must be 4mm 50-.
!
When installation has been completed, apply the FAAC stickers supplied
with the automatic door to the glass leaves.