A1400 AIR 88 532129 04 - Rev.B
98
8
V
V RX
RX
TX
TX
G
G
U/UTP CAT.5
4x2xAWG24
TX RX G K G V
J8
E1SL
LK EVO
TX RX G K G V
V RX TX G
7
99
Translation of the original instructions
ENGLISH
18. LK EVO
fw version 1.2 or later
18.1 ASSEMBLY AND TESTING
1. To separate the LK EVO use a flat screwdriver to prise apart the
points 100.
2. Break off the cable knockout.
3. Mark the points on the wall 98 and fasten the support using
suitable screws.
F
BEFORE CONNECTING THE DEVICE, disconnect the power supply and the
emergency battery of the automation.
4. Connect the E1SL board 98
5. The connection must be made using a 4-pair twisted cable
U/UTP CAT.5 4x2xAWG24 with a 0.5 mm section98-
. The
maximum distance is 50 m.
6. Assemble the parts of the LK EVO by pressing slightly on the
points 98.
* An optional connection can be made to terminals G and K on the LK EVO
with a key command to lock the function keys. With an NC contact, the
keypad is locked 98-
.
TOTAL TWO-DIRECTION AUTOMATIC
DOOR OPEN
AUTOMATIC TOTAL
ONE-DIRECTIONAL
AUTOMATIC PARTIAL
TWO-DIRECTIONAL
NIGHT
MANUAL
18.2 SELECTION MENU
1. To access the operating mode selection menu, press the cor-
responding function button.
2. The following functions may be set with the selection buttons:
- TOTAL TWO-DIRECTION AUTOMATIC
- DOOR OPEN
- AUTOMATIC TOTAL ONE-DIRECTION
- AUTOMATIC PARTIAL TWO-DIRECTION AUTOMATIC
- NIGHT
- MANUAL
3. The LED switches on to identify the active function.
4. To switch to another function press the key corresponding to
the new function.