A1400 AIR 38 532129 04 - Rev.B
L/3L/3 L/3
L
11
11
Ø 7 mm
48
3 4
1 1
3 4
5
11
9
4
3
7
7
8
9
66
10
7
8
11
Nm
8
6
2.5
Nm
2
10 mm
8 mm
6 mm
Translation of the original instructions
ENGLISH
10. INSTALLING THE GLASS LEAVES
Ø 8.5 mm
bush Ø internal 6 mm
Ø external 8 mm
Ø 6.5 mm with 45° flaring
Ø 5.0 mm with M6 tapping
Ø 7.0 mm
2 x M8
2 x M6
RISKS
PERSONAL PROTECTIVE EQUIPMENT
REQUIRED TOOLS
Ø 5-6.5 mm
45° M6 8 6-8
For manual lifting, there should be 1 person for every 20 kg to be lifted.
!
Comply with the glass thickness =
10-11 mm.
10-11 mm.
1. The glass must be drilled as shown 48-
.
2. Insert a bush in each hole in the glass 48-
.
3.
3.
Ma
Make 2 holes on the profiles of the grip
per
per 48-
-
.
.
4. Cut 2 pieces of glass beading with the length equal to L.
5. Drill holes in the seals in correspondence to the holes in the glass
48-
6.
6.
Insert
Insert the 2 seals into the profiles 48-
.
7. Clean the glass, insert the gripper.
!
Ensure the beading is in its housing.
8. Assemble the gripper as follows: Insert elements
and
into
the 2 plates
.
9. Tighten the 2 grub screws 48-
10. Part
must be aligned with the fixing holes on the carriage
50-
11. Insert 2 galvanised countersunk head screws into the holes
48-
.
!
The glass must be fully inserted until it touches the clamps on its upper
profile. If the grip of the clamp on the glass is not correct, the glass might
fall. The two clamp profiles must be aligned.
Install each leaf as described below.
1. Disassemble the 2 carriages:
- Tighten the 2 screws 49-
.
- Separate the top plate of the carriage from the bottom plate 49-
and remove the plate
.
2. Position the wheels of the upper plate unit on the sliding guide
3. 50-
(2 plates for each leaf).
4. Adjust the counter wheel to prevent the carriage from falling 50-
.
5. Place the lower plate onto the glass leaf.
- Keep to the measurements indicated in diagrams 117 - 115
and:
- 118 - 116 for RIGHT single leaf automations
- 119- 117 for LEFT single leaf automations