12.5 XM LOCK MOTOR BLOCK AND
MONITORING OPTIONAL
!
ALWAYS DISCONNECT the power supply and disconnect the emergency
battery before inserting or disabling the motor block, in order not to
damage the device.
1. Connect the motor release monitor (IF INSTALLED) to the release
terminal block 79-C.
2. Connect the motor block to the control board using the wired
connector 79-
.
3. Program the motor block operation (
EL) and enable monitoring
SU.
A
no=motor block XM LOCK disabled.
5 = motor block XM LOCK closed in NIGHT-TIME mode
6 = motor block XM LOCK closed in NIGHT-TIME and
ONE-DIRECTIONAL mode.
7= motor block XB LOCK closed in NIGHT-TIME mode
and with leaves open
8 = motor block XB LOCK closed at the end of each
movement.
C
SU=
Y (monitoring enabled)
If the motor block malfunctions, the system signals ERROR 26 on the
display and on SDK EVO.
If there is a power failure, the position of the motor block remains un-
changed. The motor block is always open in manual mode.
1
green
C
Motor block monitoring
2
pink
4
white
A
Motor block coil