Error Explanation Troubleshooting
41 Over-current detected in motor.
– Reduce the load on the motor by pedalling
more slowly.
42
Motor rotation problem.
– Turn the system off completely and turn it
back on using the button T4 on the Control
Panel. If the problem persists, please contact
the dealer or the retailer.
43
Short circuit in motor.
– Turn the system off completely and turn it
back on using the button T4 on the Control
Panel. If the problem persists, please contact
the dealer or the retailer.
44
Motor over-heated.
– Reduce the load on the motor by pedalling
more slowly or reducing the assisted
pedalling power level.
45
The software corrected an error while the
motor was rotating.
– Turn the system off completely and turn it
back on using the button T4 on the Control
Panel. If the problem persists, please contact
the dealer or the retailer.
46
No motor movement detected despite a current
level measurement of >2A.
– Turn the system off completely and turn it
back on using the button T4 on the Control
Panel. If the problem persists, please contact
the dealer or the retailer.
60 Data exchange on CAN BUS interrupted.
– Check the cables and connect all the power-
assisted pedalling system components.
70
Force applied to pedalling outside correct
range.
– Turn the system off completely and turn it
back on using the button T4 on the Control
Panel. If the problem persists, please contact
the dealer or the retailer.
71
Pedal rotation not detected.
– Turn the system off completely and turn it
back on using the button T4 on the Control
Panel. If the problem persists, please contact
the dealer or the retailer.