LengthIndex SubInde-
x
Name Value Access
1)
[Byte]
Format
SSC2, distance monitoring (OutB)
1 Set point SP1 (SP) 20 ... 300, default:
150
20x003E
2 Set point SP2 Not used 2
UIn-
teger16
0 - normally open
(NO), default
1 Switch point logic
1 – normally closed
contact (NC)
1
2 Switch point mode Not used, default:
132
1
UIn-
teger8
0x003F
3 Hysteresis (HY) 3 ... 20, default: 5
R/W
2 UIn-
teger16
SSC3, supply pressure monitoring (OutC)
1 Set point SP1
(SP.min)
4096 ... 15563,
default: 4915
20x4000
2 Set point SP2
(SP.max)
4096 ... 15563,
default: 14745
2
UIn-
teger16
0 - normally open
(NO), default
1 Switch point logic
1 – normally closed
contact (NC)
1
2 Switch point mode Not used, default:
133
1
UIn-
teger8
0x4001
3 Hysteresis (HY) Not used, default:
410
R/W
2 UIn-
teger16
1) R = read, R/W = read and write, –= no access
Tab. 26 Smart sensor profile parameters
IO-Link interface description
38 Festo — SOPA — 2020-04