SOPA--M- -2P -2N -PNLK
Switching output 2 x PNP 2 x NPN PNP/NPN, switch-
able
Switching function
OutA Threshold value comparator with variable hysteresis
OutB Threshold value comparator with variable
hysteresis
OutC Window comparator
Switching element
function
N/C contact or N/O contact, switchable
Temperature coeffi-
cient of the switching
point per 10K
[%] typ. 2
Switch-on time è Fig.21 and è Fig.22
Output current [mA] £ 100
Voltage drop [V] £ 1.5
Tab. 42 Switching output
SOPA--M- -V -B -A
Analogue output 010V 15V 420mA
Distance characteristic
curve start value
0
Distance characteristic
curve end value
300
Rise time [ms] £ 22
Load resistance of cur-
rent output
[Ω]
£ 500
Min. load resistance of
voltage output
[kΩ] ³ 20
Tab. 43 Analogue output
SOPA-
Short circuit current
rating
yes
Overload protection Present
Tab. 44 Output, additional data