SOPA-… -C -M
Adapter plate SOPA-…-
W-…
Chromated steel
–
Tab. 48 Materials
SOPA-…-M-…
Display range InA/InB
(distance)
[dimensionless] 0…500
Display range InC
(supply pressure)
1)
[bar] 0…2
Setting range threshold
value OutA/OutB (dis-
tance)
[dimensionless] 20…300
Setting range threshold
value OutC
(supply pressure)
1)
[bar] 0.5…1.9
Setting range hyster-
esis OutA/OutB (dis-
tance)
[dimensionless] 3…20
Hysteresis OutC
(supply pressure)
1)
[bar] 0.05
1) Value for InC and OutC is only shown in bar in the display.
Tab. 49 Display/operation
SOPA-… -C -M
Storage temperature [°C] –20…+80
Degree of protection IP65 (in accordance with EN 60529)
Internal air consump-
tion
[Nl/min] typ. 4.5
–
Measuring air con-
sumption (sense)
[Nl/min]
–
Typ. 15 (per measuring mod-
ule)
Exhaust air consump-
tion (clean)
[Nl/min]
–
typ. 35 (per measuring module)
Protection class III (in accordance with DINVDE0106-1)
Shock resistance 30g acceleration with 11ms duration (half-sine)
(in accordance with DIN EN60068 Part 2-27)
Technical data
53Festo — SOPA — 2020-04