For the same connection, the log le uploaded to the server contains the following data:
2021-02-11 14:25:03:Firmware version : WebdynSunPM 3.2.11.34874
2021-02-11 14:25:03:Connection 1 wait for exclusive...
2021-02-11 14:25:03:Connection requested
2021-02-11 14:25:16:Ntp synchronisation success
2021-02-11 14:25:16:Connection to 192.168.2.13:test server in
progress …
2021-02-11 14:25:16:Alarms management…
2021-02-11 14:25:16:Data acquisition management…
2021-02-11 14:25:16:Sending WPM00BDE4_MODBUS_210211_142503.csv.gz
2021-02-11 14:25:16:Data acquisition management…
2021-02-11 14:25:16:Sending WPM00BDE4_IO_210211_142507.csv.gz
2021-02-11 14:25:16:Sending WPM00BDE4_SUNSPEC_210211_142507.log.gz
2021-02-11 14:25:16:Conguration management…
2021-02-11 14:25:16:Checking WPM00BDE4_cong.ini
2021-02-11 14:25:16:No change
2021-02-11 14:25:16:Checking WPM00BDE4_daq.csv
2021-02-11 14:25:16:Sending local changes
2021-02-11 14:25:16:Remove le
2021-02-11 14:25:17:Checking WPM00BDE4_var.ini
2021-02-11 14:25:17:No change
2021-02-11 14:25:17:Checking WPM00BDE4_IO.csv
2021-02-11 14:25:17:No change
2021-02-11 14:25:17:Checking WPM00BDE4_SunSpec_inverter_SMA_Solar_
Inverter_9301_modbusTCP.csv
2021-02-11 14:25:17:Getting remote changes
2021-02-11 14:25:21:Failed to parse keep open parameter () for device
192.93.121.23:502, slave: 126, use default value true
2021-02-11 14:25:21:Local changes sent WPM00BDE4_daq.csv
2021-02-11 14:25:21:Script management...
2021-02-11 14:25:21:Checking WPM00BDE4_scl.ini
2021-02-11 14:25:21:Getting remote changes
2021-02-11 14:25:21:Checking Test script 1.lua
2021-02-11 14:25:21:No change
2021-02-11 14:25:21:Checking Test script 2.lua
2021-02-11 14:25:21:No change
2021-02-11 14:25:21:Conguration le summary:
2021-02-11 14:25:21:WPM00BDE4_SunSpec_inverter_SMA_Solar_
Inverter_9301_modbusTCP.csv: Action=Get remote le. Result=Success
2021-02-11 14:25:21:WPM00BDE4_daq.csv: Action=Send local le.
Result=Success
2021-02-11 14:25:21:WPM00BDE4_scl.ini: Action=Get remote le.
Result=Success
2021-02-11 14:25:24:Sending WPM00BDE4_SYSTEM_210211_142521.tar.gz
First features the information on the concentrator software version, then the connection to the NTP
server for time synchronisation.