E119-P
Page 70 FW_E119-P_M_v0301-02_EN
MODBUS-REGISTERS: TICKET
[d] 1612
[h] 0x64C
41613 ticket nr 1 R/W uint32 1…9999999
Representation: number of last printed ticket.
[d] 1604
[h] 0x644
41605 auto print 1 R/W uint16 0=disable 1=contract
hour
[d] 1611
[h] 0x64B
41612 print daily total 1 R/W uint16 0=no print 1=print
[d] 1605
[h] 0x645
41606 delivery mode 1 R/W uint16 0=disable 1=enable
[d] 1600
[h] 0x640
41601 delivery nr 1 R/W uint32 1…9999999
Representation: number of last finished delivery.
[d] 1610
[h] 0x64A
41611 print acc. total 1 R/W uint16 0=no print 1=print
MODBUS-REGISTERS: OTHERS
PDU
ADDRESS
HOLDING
REGISTER
VARIABLE
NO. OF
REG’S
R/W TYPE VALUES / REPRESENTATION / REMARKS
[d] 160
[h] 0x0A0
40161 model number 1 R uint16 0…9999
[d] 173
[h] 0x0AD
40174 model suffix 1 R char Representation: ASCII character
[d] 162
[h] 0x0A2
40163 firmware
version
2 R uint32 0…999999
Representation: xx.xx.xx
[d] 165
[h] 0x0A5
40166 serial number 2 R uint32 0…9999999
Representation: xxxxxxx
[d] 176
[h] 0x0B0
40177 time (local) 2 R/W uint32 00:00:00…23:59:59
Representation: hh:mm:ss
Stored decimal: 23:59:59 = 235959d = 0x0003.99B7
[d] 179
[h] 0x0B3
40180 date 2 R/W uint32 2000-01-01…2099-12-31
Representation: yyyy-mm-dd
Stored decimal: 99-12-31 = 991231d = 0x000F.1FFF
[d] 168
[h] 0x0A8
40169 password 1 R uint16 0000…9999
Representation: 4-digit number, 0000 means off.
[d] 139
[h] 0x08B
40140 keyboard lock 1 R/W uint16 0=disable 1=enable
[d] 170
[h] 0x0AA
40171 tag number 2 R/W uint32 0…9999999
Representation: xxxxxxx