EasyManua.ls Logo

Fluke 5520A - 6-89. Time Marker Function Specifications; 6-90. Wave Generator Specifications

Fluke 5520A
254 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SC300 Option
SC300 Specifications
6
6-69
6-89. Time Marker Function Specifications
Time Marker into 50 5s to 100 µs 50 µs to 2 µs1 µs to 20 ns 10 ns to 2 ns
1-Year Absolute
Uncertainty, tcal ± 5° C
±(25 + t*1000)
ppm [1]
±(25 + t*15,000)
ppm [1]
± 25 ppm ± 25 ppm
Wave Shape pulsed sawtooth pulsed sawtooth pulsed sawtooth sine
Typical Output level > 1 V pk > 1 V pk > 1 V pk > 2V p-p [2]
Sequence 5-2-1 from 5 s to 2 ns (e.g., 500 ms, 200 ms, 100 ms)
Adjustment Range At least ± 10% around each sequence value indicated above.
Resolution 4 digits
[1] t is the time in seconds.
[2] The 2 ns time marker is typically > 0.5 V p-p.
6-90. Wave Generator Specifications
Wave Generator Characteristics
Square Wave, Sine Wave, and Triangle Wave
into 50 or 1 M
Amplitude
Range into 1 M: 1.8 mV to 55 V p-p
into 50 : 1.8 mV to 2.2 V p-p
1-Year Absolute Uncertainty, tcal ±
5 °C,
10 Hz to 10 kHz
± (3% of p-p output + 100 µV)
Sequence 1-2-5 (e.g., 10 mV, 20 mV, 50 mV)
Typical DC Offset Range 0 to ± (40% of p-p amplitude) [1]
Frequency
Range 10 Hz to 100 kHz
Resolution 4 or 5 digits depending upon frequency
1-Year Absolute Uncertainty, tcal ±
5 °C
± (25 ppm + 15 mHz)
[1] The dc offset plus the wave signal must not exceed 30 V rms.