Introduction and Specifications
Additional Specifications
1
1-29
1-32. AC Current (Non-Sine Wave) Specifications
Triangle Wave &
Truncated Sine
Wave Range
p-p
Frequency 1-Year Absolute Uncertainty
tcal ± 5 °C
± (% of output + % of range)
Max
Current
Resolution
0.047 mA 0.01 Hz o 10 Hz 5.0 + 0.5 Two digits
to 0.92999 mA [1] 10 Hz to 45 Hz 0.25 + 0.5
45 Hz to 1 kHz 0.25 + 0.25 Six digits
1 kHz to 10 kHz 10 + 2
0.93 mA to 0.01 Hz to 10 Hz 5.0 + 0.5 Two digits
9.29999 mA [1] 10 Hz to 45 Hz 0.25 + 0.5
45 Hz to 1 kHz 0.25 + 0.25 Six digits
1 kHz to 10 kHz 10 + 2
9.3 mA to 0.01 Hz to 10 Hz 5.0 + 0.5 Two digits
92.9999 mA [1] 10 Hz to 45 Hz 0.25 + 0.5
45 Hz to 1 kHz 0.25 + 0.25 Six digits
1 kHz to 10 kHz 10 + 2
93 mA to 0.01 Hz to 10 Hz 5.0 + 0.5 Two digits
929.999 mA [1] 10 Hz to 45 Hz 0.25 + 0.5
45 Hz to 1 kHz 0.25 + 0.5 Six digits
1 kHz to 10 kHz 10 + 2
0.93 A to 10 Hz to 45 Hz 0.5 + 1.0
8.49999 A 45 Hz to 1kHz 0.5 + 0.5
1 kHz to 10 kHz 10 + 2 Six digits
8.5 A to 57 A [2] 45 Hz to 500 Hz 0.5 + 0.5
500 Hz to 1 kHz 1.0 + 1.0
[1] Frequency limited to 1 kHz with LCOMP on.
[2] Frequency limited to 440 Hz with LCOMP on