PCM PCA - This PCA is located inside the PCM and monitors internal PCM
sensors and pulses the control solenoids. The PCA contains the control
algorithm, monitors the primary pressure directly from the selected PMM, and
interfaces with the main PCA.
LED indication (located on the PM600 module PCA - visible when you service
the PM600 module):
Application running - on/off blink at 1 second intervals
Application running, no communication - on/off blink at 2-second intervals
Downloading or no application loaded - pause, double blink
Not functioning - full on or full off
Communications / Firmware
Figure 5 shows a high-level summary of the communication inside the Product
chassis. The main PCA and front-panel interface communicate with USB. The
main PCA, solenoid drivers, PMM, and PCM interface communicate over a
canbus interface.
Back Panel -- Comms PCA Tray
USB / RS-232 / CANbus / ExtDrivers / Switch
Main Processor FPGA
GPIB
Front Panel
Solenoid Driver PCAs
Display / Touch Keys Knob
Display Processor
Sol Drivers
6270-4003
Processor
CANUSB
USB
ID
ID
Sol Drivers
6270-4005
ID
CAN
Press
Temp
PMM Sensor
Processor
CAN
Press
Temp
PMM Sensor
Processor
CAN
Press
Temp
PMM Sensor
Processor
CAN
Press
Temp
PMM Sensor
Processor
CAN
Press
Temp
PMM Sensor
Processor
CAN
P, T,
Valves
Controller
Processor
hxn309.eps
Figure 5. Communications/Firmware Block Diagram