EasyManua.ls Logo

Fluke 6270A - Inspect the Control Valves

Fluke 6270A
144 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6270A
Service Manual
64
Note
Make sure to not interchange the coils or valves between
apply/release valves.
a. Use a 3/4 inch wrench and remove the coil-retaining nut from the
control valve (apply) coil or (release) coil . This should only be hand
tight or very loosely tightened with a 3/4 inch wrench.
b. Remove the coil for the valve to be inspected or replaced.
c. Remove the four screws with a # 2 Phillips screwdriver and remove
entire valve assembly.
d. Inspect the valve by using a 7/8 inch deep socket or open wrench to
remove the valve stem from the valve base .
To install the valves, reverse these steps.
Inspect the Control Valves
To inspect the control valves, see Figure 37:
1. After the control valve is removed as detailed in the Removing Control Valves
section, inspect the valve-body surface and valve-base orifice to make
sure no damage, particles, or contamination exists. The Product ships with
blue color material on the valve body .
2. Make sure the shim is installed in the valve shaft. If not installed, poor
control and a loud buzzing sound in the control results.
3. Verify the valve assembly order .
2
1
D
4
B
C
A
3
hxn405.eps
Figure 37. Internal Valve Inspection

Table of Contents