IMPORTANT! Fronius recommends a flat rate in order to avoid unforeseeable data vol-
umes.
Calculation Ex-
amples
Example 1 - Home System
1 inverter;
No Fronius Sensor Card/Box;
Fronius Datamanager 2.0 has a
24-hour internet connection
+ 0.15 KB
+ 32 KB/h x 24 h = 768 KB
Archived data is sent to Fronius So-
lar.web;
30 minutes transfer time;
Inverters operate 14 h/day;
15 minutes storage interval;
(This results in 1 memory sector per day in
accordance with Section "Calculating
Memory Capacity")
+ 0.6 KB/min x 30 min = 18 KB
+ (1 memory sector/day x 4 KB) + 8 KB = 12
KB
Real-time data is viewed over a 15-minute
period every day
+ 42 KB/h x 0.25 h = 10.5 KB
1 service message sent each day to con-
firm average error rate
+ 1 service message x 1 KB = 1 KB
Subtotal without safety 0.15 KB
768.00 KB
18.00 KB
12.00 KB
10.50 KB
1.00 KB
809.65 KB
A 10% safety factor is added to the calcu-
lation
809.65 KB + 10%
Final result 890.615 KB/day

Table of Contents

Other manuals for Fronius Datamanager 2.0

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Datamanager 2.0 and is the answer not in the manual?

Fronius Datamanager 2.0 Specifications

General IconGeneral
Monitoring PlatformFronius Solar.web
Communication InterfacesEthernet
ProtocolsModbus TCP
Data LoggingIntegrated data logger
Web InterfaceYes
CompatibilityFronius inverters
Power SupplyVia inverter
MountingWall mounting

Related product manuals