998 Fronius Solar.net loop is
open 24 hours
Fronius Solar.net is not closed
and X-LED on Datalogger or
Datamanager lights up red
1. Check Fronius Solar.net
loop
2. Check network cable
3. Check Fronius Com Card
999 No power fed into mains for
a 24-hour period
1. No answer from inverter for
24 hours -> Notification to Dat-
alogger or Datamanager
1. Check LED status of Data-
manager or Datalogger
2. No answer from Fronius
Sensor Card for 2 hours -> No-
tification to Datalogger or Data-
manager
2. Check Fronius Solar.net
loop and archive values
1000* -
1001*
Service messages Harmless if energy is being fed
into the grid correctly - pro-
vides information on the status
of the internal processor
1201* -
1210*
Service messages Harmless if energy is being fed
into the grid correctly - pro-
vides information on the status
of the internal processor
* ... Code only appears during event logging and on the error counter
Code Description Behaviour Remedy

Table of Contents

Other manuals for Fronius Primo 3.0-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Primo 3.0-1 and is the answer not in the manual?

Fronius Primo 3.0-1 Specifications

General IconGeneral
PurposeSolar panel
Efficiency98 %
Output power3000 W
Input current12 A
Input voltage80 - 1000 V
Output voltage- V
Input frequency50 - 60 Hz
Power supply typeAuto
Adjustable output voltage-
International Protection (IP) codeIP65
Product colorBlack, Grey
Built-in displayYes
Operating temperature (T-T)-40 - 55 °C
Weight and Dimensions IconWeight and Dimensions
Depth204 mm
Width431 mm
Height645 mm
Weight21500 g