EasyManua.ls Logo

Fronius Primo 3.0-1 - Page 132

Fronius Primo 3.0-1
160 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
132
The device data unit of the new
RECERBO must also be broken off
and returned to Fronius with the faulty
RECERBO.
Connect the broken off device data unit
(4) to the inside of the new RECERBO
Fit the RECERBO holder (3) to the new
RECERBO
- feed it in from above
- press downwards
Insert the new RECERBO module
The RECERBO holder locking devices
(2) must be fully engaged in the
housing shell
Insert the external fan cable into the
cable guide (1)
Insert the Datamanager card, close the
inverter and place it in the wall bracket
(see "Replacing the Datamanager
card" and "Opening and closing the de-
vice" sections)
(4) (3)
NOTE! If you forget to connect the
device data unit or do not connect
it correctly, the inverter will show
status code 482 on the display.
NOTE! All guide bolts and pins
must be properly engaged.
1
2
3
(1)
(2) (2)
4
5
6
7