AC input/output data
Nominal output power (P
nom
) 5000 W
Max. output power 5000 W
Rated apparent power 5000 W
Nominal mains voltage 3 ~ NPE 220 V / 380 V
3 ~ NPE 230 V / 400 V
Min. mains voltage
154 V
1)
Max. grid voltage
280 V
1)
Max. output current 8 A
Nominal output current (at 230 V) 7.2 A
Current (inrush)
6)
9.9 A / 4 ms
Nominal frequency
50 / 60 Hz
1)
Initial short circuit alternating cur-
rent / phase I
K
8 A
Total harmonic distortion < 3.5%
Power factor cos phi
2)
0 - 1 (adjustable)
0.7 - 1 (recommended)
Max. permitted mains impedance Z
max
at PCC
4)
None
Maximum output fault current / dura-
tion
7.5 A / 157 ms
AC output data PV Point
Max. output power 4133 W (for 5 s)
Rated power 3000 W
Nominal output current 13 A
Nominal mains voltage 1 ~ NPE 220 V / 230 V / 240 V
Nominal frequency
53 / 63 Hz
1)
Switchover time < 90 s
Power factor cos phi
2)
0 - 1
General data
Maximum efficiency 98.2%
European efficiency (U
mpp nom
) 97.5%
European efficiency (U
mpp max
) 97%
European efficiency (U
mpp min
) 96.2%
Self-consumption at night < 10 W
Cooling Controlled forced-air ventilation
Protection class IP 66
Dimensions H x W x D 530 x 474 x 165 mm
Weight 16.5 kg