TPS/MW 5000
600/575-460 V
auto-transfor-
mer
Mains voltage 1 (+/- 10 %) 3 x 600 V / 50 / 60 Hz
Mains voltage 2 (+/- 10 %) 3 x 575 V / 50 / 60 Hz
Output voltage (+/- 10 %) 3 x 460 V / 440 V
Mains fuse protection (slow-blow) 25 A (600V)
25 A (575 V)
Fan fuse (slow-blow) 0.4 A
Maximum apparent power 27.6 kVA
Effective apparent power 20.7 kVA
Cos phi 0.9
Maximum primary current for
Mains voltage 1 (600V)
Mains voltage 2 (575 V)
27 A
28 A
Effective primary current for
Mains voltage 1 (600V)
Mains voltage 2 (575 V)
20 A
21 A
Secondary current at
10 min / 40 °C
40 % d.c.*
10 min / 40 °C
100 % d.c.*
33 A
26 A
Protection IP 23
Type of cooling F
Insulation class F
Dimensions l x w x h 625 x 290 x 230 mm
25.59 x 11.42 x 9.06 in.
Weight 47,5 kg
104.72 lbs
Marks of conformity CSA
* duty cycle