73
EN
Signal waveform when selecting via job number with
limit signal (warning)
(1) Gas pre-flow time
(2) Starting current
(3) Welding current
(4) End current
(5) Gas post-flow time
Robot ready
(Robot ready)
Source error reset
(Source error reset)
Mode bit 1
(Job / Program bit 0-7)
Job number
(Job mode)
NOTE! Further information is available in the „Fronius-recom-
mended procedures“ sub-section
Welding start
(Welding start)
Error Limit, Warning
(Warning)
Process active signal
(Process active)
Arc stable
(Arc stable)
Main current signal
(Main current signal)
Power source ready
(Power source ready)
Error number
(Error number)
(1) (2) (3) (4) (5)