Error number
UBST
81 tP7 | hot Overtemperature in the transformer
Allow device to cool down
82 Err | EHF Overtemperature in external HF
Allow device to cool down
83 PHA | SE The number of phases has changed
Check mains voltage
84 No | Gas Problem with gas supply
Check gas supply
86 Err | db No CMTL licence
Load CMTL firmware on device
100 Und | Opc HOST error - Contact After-Sales Service
101 Prt | FIt HOST error - Contact After-Sales Service
102 III | Opa HOST error - Contact After-Sales Service
103 III | Ina HOST error - Contact After-Sales Service
104 III | Bus HOST error - Contact After-Sales Service
105 Err | 105 HOST error - Contact After-Sales Service
106 STK | OVL HOST error - Contact After-Sales Service
107 STK | UVL HOST error - Contact After-Sales Service
108 Err | Dog HOST error - Contact After-Sales Service
109 ASS | Ert HOST error - Contact After-Sales Service
110 Edg | 1 HOST error - Contact After-Sales Service
150 Nothing Power source switched off or no mains voltage
Switch on power source or check mains voltage
Error
no.
Front display Error description
Remedy
Error
no.
Front display Error description
Remedy
63 EIF | 1.1 No software configuration - Contact After-Sales Service
63 EIF | 1.2 Wrong bus module - Contact After-Sales Service
63 EIF | 1.3 Bus module not initialised - Contact After-Sales Service
63 EIF | 2.1 Installation set ROB I/O not connected - Contact After-Sales
Service
63 EIF | 3.1 Invalid interbus cycles occurred
Check data lines, otherwise contact After-Sales Service
63 EIF | 4.x Error in CFM, x stands for
1...CFM not found
2 - 8...Internal error
Contact After-Sales Service
63 EIF | 5.x Error in EEprom 2464, x stands for
1...Read error EEprom 1
2...Write error EEprom 1
3...Invalid data EEprom 1
4...Read error EEprom 2
5...Write error EEprom 2
6...Invalid data EEprom 2
Contact After-Sales Service
63 EIF | 6.x Error in Anybus-S module x stands for
1 - 8...Internal error
Contact After-Sales Service