62
65 hot | H2O Overtemperature in cooling system - Wait until the end of the
cooling phase
66 tJo | XXX JobMaster overtemperature (xxx stands for the temperature
indicator)
Allow machine to cool down
67 Err | tJo Jobmaster temperature sensor faulty - Contact After-Sales
Service
68 Err | 068 Secondary safety cut-out - Contact After-Sales Service
69 Err | 069 Illegal mode change during welding
Reignite
70 Err | 70.x Gas error - x stands for
1... Gas sensor not found
2....No gas
3....Calibration error
4....Faulty solenoid valve
5....Solenoid valve not found
6....Check gas supply
71 Err | 71.X Limit error, X stands for:
1... Upper current limit exceed
2....Lower current limit exceed
3....Upper voltage limit exceed
4....Lower voltage limit exceed
5....Exceed of upper vD limit
6....Exceed of lower vD limit
72 Err | Cfg Configuration change (total current or Twin)
Check LHSB link
73 noH |ost Host computer not found
Check connection to power source and its software version
74 Touch Internal dummy for the Touchsensing display on the RCU
I5000
Contact After-Sales Service
75 Err | 75.x MMArc error (BIAS200 only), X stands for:
1... Null balance error
2....Data for LN_CFGMEMS faulty
4....Data for LN_GETDEVICEVERSION faulty
Contact After-Sales Service
77 Err | 77.x Motor overcurrent, X stands for:
1... Exceed of upper current limit
2....Exceed of lower current limit
3....Exceed of upper voltage limit
4....Exceed of lower voltage limit
5....Exceed of upper vD limit
6....Exceed of lower vD limit
7....Primary motor current exceed
8... PPU motor current exceed
78 E-Stop Emergency stop - Contact After-Sales Service
79 Err | U0.x VRD error Limitation of open-circuit voltage
1... Voltage exceed in instrument lead
2....Short circuit in instrument lead
3....Timeout
Contact After-Sales Service
80 Err | 080 Wirefeeder error. Device has become unplugged during weld-
ing
Check wirefeeder
Error
no.
Front display Error description
Remedy