35 DSP | Sy DSP error - Contact After-Sales Service.
36 DSP | nSy DSP error - Contact After-Sales Service.
37 US | POL HOST error - Contact After-Sales Service.
38 -St | op- Robot not ready
Set “Robot ready” signal and “Source error reset”
39 No | H20 Flow watchdog - Check cooling unit
40 Err | Lic The licence key is faulty
Check licence key
49 Err | 049 Intermediate circuit-balance error
Contact After-Sales Service
50 Err | 050 Phase failure
Check the mains fuse protection, the mains supply lead and
plug
51 Err | 051 Mains undervoltage: mains voltage has fallen below lower lim-
it of tolerance range (+/- 15 %)
Check the mains voltage
52 Err | 052 Mains overvoltage: mains voltage has exceeded upper limit of
tolerance range (+/- 10 %)
Check the mains voltage
53 Err | PE Ground (earth) fault
Remove ground (earth) fault
54 Err | 054 Wire stick control
Detach wire short circuit
55 No | IGn “Ignition time-out” fault: no ignition occurred within set wire
length
Check wirefeeder
56 Err | 056 “Wire end” fault: no more wire available (only if wire sensor
available)
Insert new wirespool
57 No | GAS “Gas flow” fault: no gas flowed out within one second after gas
pre-flow time began
Check gas supply
58 No | Arc “Arc-break monitor” fault: After the arc breaks, no new arc ap-
pears within the timespan set for the “Arc” parameter (Set-up
menu 2nd)
Reignite
59 Err | 059 Secondary overvoltage: safety cut-out has tripped
Check secondary circuit, including TPCEL40 PCB
60 Err | 060 DPS500 only: SITRE1A has activated the safety cut-outClose
the plasma reactor door (closes external contact).
Reset Err | 060 by briefly removing the start signal
61 Err | Arc DPS500 only: Digital signal processor (DSP) detected several
unwanted arcs in quick succession
Reset “Err | Arc“ by briefly removing the start signal
62 Err | 062 TP08 overtemperature
Wait until the end of the cooling phase
63 EIF | xxx Interface fault
Further details in the Interbus 2MB operating instructions
64 Err | tf8 Faulty cooling unit temperature sensor - Contact After-Sales
Service
Error
no.
Front display Error description
Remedy