60
3 ts2 | xxx Over-temperature in secondary circuit of the machine
Allow machine to cool down
4 ts3 | xxx Over-temperature in secondary circuit of the machine
Allow machine to cool down
5 tp1 | xxx Over-temperature in primary circuit of the machine
Allow machine to cool down
6 tp2 | xxx Over-temperature in primary circuit of the machine
Allow machine to cool down
7 tp3 | xxx Over-temperature in primary circuit of the machine
Allow machine to cool down
8 tp4 | xxx Over-temperature in primary circuit of the machine
Allow machine to cool down
9 tp5 | xxx Over-temperature in primary circuit of the machine
Allow machine to cool down
10 tp6 | xxx Over-temperature in primary circuit of the machine
Allow machine to cool down
11 Err | tf1 Temperature sensor fault (short circuit or open circuit)
Contact After-Sales Service.
12 Err | tf2 Temperature sensor fault (short circuit or open circuit)
Contact After-Sales Service.
13 Err | tf3 Temperature sensor fault (short circuit or open circuit)
Contact After-Sales Service.
14 Err | tf4 Temperature sensor fault (short circuit or open circuit)
Contact After-Sales Service.
15 Err | tf5 Temperature sensor fault (short circuit or open circuit)
Contact After-Sales Service.
16 Err | tf6 Temperature sensor fault (short circuit or open circuit)
Contact After-Sales Service.
17 DSP | E05 DSP error - Contact After-Sales Service.
18 Err | bPS DSP error - Contact After-Sales Service.
19 Err | IP DSP error - Contact After-Sales Service.
20 Err | AXX DSP error - Contact After-Sales Service.
21 Err | EXX DSP error - Contact After-Sales Service.
22 Err | EPF HOST error - Contact After-Sales Service.
23 Err | 23.X HOST error - Contact After-Sales Service.
24 Err | 24.X HOST error - Contact After-Sales Service.
25 Err | 25.X HOST error - Contact After-Sales Service.
26 Err | 26.X HOST error - Contact After-Sales Service.
27 Err | 027 HOST error - Contact After-Sales Service.
29 DSP | CXX DSP error - Contact After-Sales Service.
30 Efd | XX.Y Fault in wirefeeding system (XX and Y -> error list SR40)
Check wirefeeding system
31 Err | 31.X HOST error - Contact After-Sales Service.
32 Ecf | XXX HOST error - Contact After-Sales Service.
33 tst | XXX Over-temperature in the control circuit
Allow machine to cool down
34 Err| tt7 Temperature sensor fault (short circuit or open circuit)
Contact After-Sales Service
Error
no.
Front display Error description
Remedy

Table of Contents