HEATING CAPACITY
TC : Total Capacity kW.
MODEL : AS
E12GACH
Outdoor Temperature
Indoor temperature
16°CDB 18°CDB 20°CDB 21°CDB 22°CDB 24°CDB 26°CDB
(°CDB) (°CWB) TC TC TC TC TC TC TC
-19.3 -20.0
2.1 2.1 2.1 2 .1 2.1 2 .1 2.1
-15.0 -16.0 2.5 2.5 2.5 2.4 2.4 2.4 2.4
-12.0 -13.0 2.7 2.7 2.7 2.7 2.7 2.7 2.7
-9.0 -10.0 3.0 3.0 3.0 3.0 3.0 3.0 2.9
-7.0 -8.0 3.2 3.2 3.2 3.2 3.1 3 .1 3.1
-5.0 -6.0 3.4 3.4 3.4 3.3 3.3 3.3 3.2
-3.0 -4.0 3.6 3.6 3.5 3.5 3.5 3.5 3.2
-1.0 -2.0 3.8 3.7 3.7 3.7 3.7 3.5 3.2
0.0 -1.0 3.9 3.8 3.8 3.8 3.8 3.5 3.2
2.0 1.0 4.1 4.0 4.0 3.9 3.8 3.5 3.3
5.0 4.0 4.4 4.3 4.1 4.0 3.8 3.6 3.3
7.0 6.0 4.5 4.4 4.1 4.0 3.8 3.6 3.3
9.0 7.8 4.6 4.4 4.1 4.0 3.8 3.6 3.3
12.0 10.6 4.6 4.4 4.1 4.0 3.8 3.6 3.3
15.0 13.5
4.6 4.4 4.1 4.0 3.8 3.6 3.3
MODEL : AS
E14GACH
Outdoor Temperature
Indoor temperature
16°CDB 18°CDB 20°CDB 21°CDB 22°CDB 24°CDB 26°CDB
(°CDB) (°CWB) TC TC TC TC TC TC TC
-19.3 -20.0
2.6 2.6 2.6 2.6 2.6 2.6 2.6
-15.0 -16.0 3.0 3.0 3.0 3.0 3.0 3.0 3.0
-12.0 -13.0 3.3 3.3 3.3 3.3 3.3 3.3 3.3
-9.0 -10.0 3.7 3.7 3.6 3.6 3.6 3.6 3.6
-7.0 -8.0 3.9 3.9 3.9 3.9 3.8 3.8 3.8
-5.0 -6.0 4.1 4.1 4.1 4.1 4.1 4.0 3.9
-3.0 -4.0 4.4 4.3 4.3 4.3 4.3 4.3 4.0
-1.0 -2.0 4.6 4.6 4.5 4.5 4.5 4.3 4.0
0.0 -1.0 4.7 4.7 4.7 4.6 4.6 4.3 4.0
2.0 1.0 5.0 4.9 4.9 4.8 4.6 4.3 4.0
5.0 4.0 5.3 5.3 5.0 4.8 4.7 4.3 4.0
7.0 6.0 5.5 5.3 5.0 4.8 4.7 4.3 4.0
9.0 7.8 5.7 5.3 5.0 4.8 4.7 4.3 4.0
12.0 10.6 5.7 5.3 5.0 4.8 4.7 4.3 4.0
15.0 13.5
5.7 5.3 5.0 4.8 4.7 4.3 4.0
- (02 - 58) -
MODEL
SELECTION
MODEL
SELECTION