Note : Specications are based on the following conditions.
Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m.
MEDIUM STATIC PRESSURE DUCT TYPE2-5.
Model name ARXA24GBLH ARXA30GBLH ARXA36GBLH ARXA45GBLH
Power source 230V ~, 50Hz
Available voltage range 198 to 264 V
Capacity
Cooling
kW
7.1 9.0 11.2 12.5
Heating 8.0 10.0 12.5 14.0
Input power W 94 108 194 240
Static pressure range Pa 0 to 150
Standard static pressure Pa 40 50 50 60
Fan
Airow rate
High
m
3
/ h
(l / s)
1,280
(356)
1,410
(392)
1,840
(511)
1,970
(547)
Med
990
(275)
1,280
(356)
1,600
(444)
1,860
(517)
Low
840
(233)
1,150
(319)
1,470
(408)
1,640
(456)
Type x Quantity Sirocco × 2
Motor output W 106 197
Sound pressure
level
High
dB(A)
31 34 37 41
Med 27 32 35 38
Low 23 29 33 36
Heat exchanger
Length
mm
1,000
Fin pitch 1.40
Rows x Stages 3 × 14 4 × 14
Face Area m
2
0.29
Pipe type (Material) Grooved H-pin (Copper)
Fin
Type (Material) Slit(Aluminium)
Surface
treatment
Hydrophilic coating
Air lter (Option)
Model name UTD-LF25NA
Type Fungicide type
Net material PP honeycomb
Enclosure
Material galvanized sheet iron
Colour -
Dimensions
(H x W x D)
Net
mm
270 × 1,135 × 700
Gross 300 × 1,320 × 790
Weight
Net
kg
36 40
Gross 44 48
Connection
pipe diameter
Liquid (Flare)
mm
ø 9.52
Gas (Flare) ø 15.88 ø 19.05
Drain hose VP25 [ø 25(I.D.) ; ø 32(O.D.)]
- (04 - 19) -
INDOOR
UNITS
INDOOR
UNITS