2.1.2 Switching On and Off the PSU Switch on the Power Supply Unit
This section explains how to move the PSU switch of the power supply unit of the controller enclosure and
drive enclosures (2.5" type/3.5" type) to the ON and OFF positions in each enclosure. Note that power supply
units for high-density drive enclosures do not have PSU switches.
To Switch to ON
Turn the PSU switch of the power supply unit to the ON position (marked "|").
Make sure all of the PSU switches are in the ON position.
Figure 2.5 ON Position (Marked "|") of the PSU Switch on a Power Supply Unit
Power supply unit (PSU#0) Power supply unit (PSU#1)
AC power is supplied to an enclosure.
For the controller enclosure, the POWER LED on the power supply unit blinks green.
For the drive enclosure, the POWER LED on the power supply unit emits green lights and the fan revolves at
high speed for 30 seconds.
Drive enclosure
Controller enclosure
Power supply unit (PSU#1)Power supply unit (PSU#0)
POWER
LED
Chapter 2
Basic Operation
2.1 Powering On and Off
53
FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AM-7662-09ENZ0