About Static Electricity
Do
When handling SFP+ modules, make sure to wear a wrist strap or touch a metal
part to discharge the human body's natural static electricity.
Failure to discharge static electricity may cause device failure.
Leave the SFP+ module in its package until ready to install it.
About Shock
Do Not
Do not handle SFP+ modules roughly or subject them to physical shocks when lay-
ing them down.
Do not place any objects on top of SFP+ modules.
Do not knock or drop SFP+ modules on hard objects.
5.3.4 Long Wave SFP+ Modules (16Gbit/s) Installation Procedure
This section describes how to replace a Short wave SFP+ module (16Gbit/s) in the host interface (FC 16Gbit/s)
with a Long wave SFP+ module (16Gbit/s).
Do
If SFP+ modules are installed in a way other as described here, damage and/or de-
vice failure or electrical shock may occur.
1 Check that all components of the ETERNUS DX are in normal status, using the [Storage System Status]
screen of ETERNUS Web GUI.
2 Check the port location of the Short wave SFP+ module (16Gbit/s) that is to be replaced by using the
Internal Parts information in the [Channel Adapter Detail] screen.
Note that a Short wave SFP+ module (16Gbit/s) is displayed as "16G SFP+(MMF)" in the "SFP Type" field.
3 Turn off the ETERNUS DX.
Refer to "2.1.4 Powering Off" (page 56) for details on how to turn off the ETERNUS DX.
Chapter 5
Component Expansion/Function Enhancement
5.3 Installing Long Wave SFP+ Modules (16Gbit/s)
101
FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AM-7662-09ENZ0