7.5.6 Replacing the 4 x 2.5-inch HDD backplane (right
side) or PCIe SSD backplane
Field Replaceable Unit
(FRU)
Hardware: 5 minutes
Tools: tool-less
Preliminary steps
â–¶
"Locating the defective server" on page 43
.
â–¶
"Shutting down the server" on page 45.
â–¶
"Disconnecting the power cord" on page 46.
â–¶
"Getting access to the component" on page 48.
â–¶
Release all HDD/SSD modules and pull them out a few centimeters, see
"Removing a 2.5-inch HDD/SSD module" on page 156.
CAUTION
The HDD/SSD modules need not to be removed.
â–¶
If you want to remove them nevertheless, check if all HDD/SSD
modules are uniquely identified so that you can reinsert them
into their original bays.
â–¶
Release all dummy modules and pull them out a few centimeters, see
"Removing the 2.5-inch dummy module" on page
153
.
Hard disk drive (HDD) / solid state drive (SSD)
RX1330 M4 Upgrade and Maintenance Manual 163